Our website offers parametric search capabilities allowing our customers to search for parts through a number of filters, one of which is by National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. ASAP Inventory has a broad selection of NSN parts 907178335-02 such as 5910014851070 from manufacturers like Sager Electrical Supply Co Inc. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-485-1070 Item Description: Capacitor Fixed Cer | 5910 | 014851070 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
907178335-02 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CRTL | CRITICALITY CODE JUSTIFICATION | AGAV |
ABJT | TERMINAL LENGTH | 1.250 INCHES NOMINAL |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -30.0 TO 30.0 SINGLE SECTION |
SR-1 | SPEC/STD CONTROLLING DATA | |
SR-1 | MANUFACTURERS CODE | 81349 |
CWJK | CASE MATERIAL | PLASTIC |
ADAU | BODY HEIGHT | 0.140 INCHES NOMINAL |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-C-20/37 |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.0000 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | CCR07CG333FM |
CQBQ | CAPACITANCE VALUE PER SECTION | 33000.000 PICOFARADS SINGLE SECTION |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.400 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | 4920-33-202-4105,5998-33-201-5528 |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -1.00/+1.00 PERCENT SINGLE SECTION |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.15 |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-20 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
ADAQ | BODY LENGTH | 0.480 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.480 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |