7025015787945 | 5985014980332 |
5985013243461 | 1510000808414 |
7025015588807 | 7010015006979 |
5905000000136 | 6135014938794 |
7025014906701 | 6150012089751 |
View All |
Our website offers parametric search capabilities allowing our customers to search for parts through a number of filters, one of which is by National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. ASAP Inventory has a broad selection of NSN parts 32411-0-212DEGFP such as 5930000153542 from manufacturers like Radiodetection Corporation. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-015-3542 Item Description: Switch Thermostatic | 5930 | 000153542 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
32411-0-212degfp | 2 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 1.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.406 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.344 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 212.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 208.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |
ABKW | OVERALL HEIGHT | 0.406 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.776 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.250 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SINGLE VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote