Our website offers parametric search capabilities allowing our customers to search for parts through a number of filters, one of which is by National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. ASAP Inventory has a broad selection of NSN parts MTE-2652 such as 5950011747692 from manufacturers like Magnespec Inc. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-174-7692 Item Description: Transformer Power | 5950 | 011747692 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Mte-2652 | 5 | 1 | C | 9 |
MRC | Criteria | Characteristic |
---|---|---|
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.0016 |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.355 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.395 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 7.780 INCHES MINIMUM AND 7.840 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM SINGLE COMPONENT AND 450.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 4.67 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | 2 PRIMARY WINDINGS; 9 SECONDARY WINDINGS; 5TH,6TH,7TH AND 8TH WINDINGS ARE CENTER TAPPED |
TEST | TEST DATA DOCUMENT | 57057-8892400042 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND VIBRATION RESISTANT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.303 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 7.323 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 7.000 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.271 INCHES MINIMUM SINGLE GROUP AND 0.291 INCHES MAXIMUM SINGLE GROUP |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 2.494 KILOVOLT-AMPERE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 8.100 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT |
CRMJ | WINDING POWER RATING | 50.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 26 SCREW |