Our website offers parametric search capabilities allowing our customers to search for parts through a number of filters, one of which is by National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. ASAP Inventory has a broad selection of NSN parts 175614-101 such as 5950013968620 from manufacturers like Harris Llc. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-396-8620 Item Description: Transformer Power | 5950 | 013968620 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
175614-101 | 5 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
TEST | TEST DATA DOCUMENT | 77245-175614 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
ZZZK | SPECIFICATION/STANDARD DATA | 77245-175614-101 MANUFACTURERS SOURCE CONTROL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.540 INCHES MINIMUM AND 2.580 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AAJD | (NON-CORE DATA) THREAD CLASS | 2B |
SR-1 | MFR SOURCE CONTROLLING REFERENCE | 175614-101 |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
FEAT | SPECIAL FEATURES | WINDINGS 1 THROUGH 4 ARE INTERNALLY CONNECTED TO CENTER TAP OF WINDING NO 5 |
ADAT | BODY WIDTH | 2.300 INCHES MAXIMUM |
SR-1 | MANUFACTURERS CODE | 77245 |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAJF | (NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND |
CRBZ | WINDING OPERATING CURRENT | 1.23 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 1.17 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 470.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 366.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
SR-1 | SPEC/STD CONTROLLING DATA | |
ADAU | BODY HEIGHT | 1.490 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.970 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |