7025015787945 | 5985014980332 |
5985013243461 | 1510000808414 |
7025015588807 | 7010015006979 |
5905000000136 | 6135014938794 |
7025014906701 | 6150012089751 |
View All |
Our website offers parametric search capabilities allowing our customers to search for parts through a number of filters, one of which is by National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. ASAP Inventory has a broad selection of NSN parts EA2B0224012ADC such as 5925014972042 from manufacturers like Electric Boat Corporation. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-497-2042 Item Description: Circuit Breaker | 5925 | 014972042 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ea2b0224012adc | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 50.0 AC ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | PIN |
CPRQ | RESET METHOD | MANUAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.460 INCHES MINIMUM AND 3.580 INCHES MAXIMUM |
THSD | THREAD SERIES DESIGNATOR | UNC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.480 INCHES MINIMUM AND 3.614 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | DOUBLE POLE, SINGLE THROW, NORMALLY OPEN |
AKPX | POLE QUANTITY | 2 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
ADAQ | BODY LENGTH | 5.125 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.072 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.996 INCHES MINIMUM AND 1.056 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.750 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | WEAPON LAUNCH CONSOLE ASSEMBLY FOR LOSANGELES CLASS SUBMARINE 688 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 1000.0 ALL LOCATIONS |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
FEAT | SPECIAL FEATURES | MOUNT CIRCUIT BREAKER IN VERTICAL POSITION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CMLP | THREAD QUANTITY PER INCH | 32 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.026 INCHES NOMINAL |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 5.0 AC AND 1.0 DC |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-55629/15 GOVERNMENT SPECIFICATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 0.800 MINIMUM AND 7.000 MAXIMUM ALL LOCATIONS |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 50.0 DC |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.150 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT AND 0.032 MINIMUM AT 400 PCT AND 0.250 MAXIMUM AT 400 PCT AND 0.110 MAXIMUM AT 800 PCT ALL LOCATIONS |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
AJEC | BOSS HEIGHT | 0.220 INCHES NOMINAL |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
ADTV | CASE MATERIAL | PLASTIC |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT WATER RESISTANT |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote